Fire rated sectional doors
Where fire safety is a priority
Safe and reliable fire-rated overhead doors
Meet the set requirements and standards
Our fire-rated overhead doors are designed to provide extra safety in the event of a fire. They have been tested and comply with European standards. The doors resist fire and smoke and are suitable for use in buildings where fire safety is important. The panels are made of fire-resistant composite and have a white texture. The door is 42 mm thick as standard. Various drive systems are available, depending on the size of the door. A control box is always included. Signalling and security are standard features.

Use of the fire-rated industrial doors
The doors are always installed on the face of the opening. They are suitable for various surfaces such as concrete, masonry, aerated concrete or fire-resistant coated steel structures. The door is suitable for indoor areas and for passageways from indoors to outdoors. You can use this door in protected escape routes, but not as an actual escape route. The door is designed for frequent use. It has been tested with more than 50,000 opening and closing movements.
We are happy to advise you
Our website contains a wealth of information, but sometimes a customised approach is required. Our specialists are on hand to provide advice tailored to your situation. Contact us by email or telephone. Together, we will find the best solution for your business.
Options, standards and certifications for fire-rated overhead doors
OHD-C EI(1) 60 | OHD-C EI(2) 90 | EW 60
Certification and standards
The fire-rated overhead door is CE marked and tested according to several European standards:
- EN 1634-1 en EN 1634-3 (fire and smoketest)
- EN 13501-2 (fire classification)
- EN 13501-1, fire class B-s1, d0 (for the panels)
- Cycle test according to class C3 (> 50,000 opening/closing cycles)
- EN 13241 and EN 16034 (safety and performance)
Application
- suitable for indoor / indoor and indoor / outdoor situations
- applicable in protected escape routes, not as an escape route
- suitable for frequent use
- mounting only possible on the wall / opening
- permissible mounting surfaces include: aerated concrete, sand-lime brick, concrete, masonry, fire-resistant steel construction
Standard configuration
Each door is standardly equipped with:
- gravity failsafe chain wheel drive 400 V incl. control box
- external gravity failsafe tubular motor 230 V incl. control box (till ± 13 m²)
- Anti-fall safety mechanism
- Visual and audible indicators
- rail system for installation height between 1.000 mm and 1.500 mm
- door leaf constructed from fire-resistant composite panels, thickness 42 mm, with a mixed white structure
Optional features
The door can be fitted with:
- application in indoor / outdoor situations up to wind class 5 (> 1.000 Pa)
- smoke-resistant version based on Sa or S200
- burglar-resistant version (outside => inside) in accordance with RC 2 or RC 3
- sound insulation value 30 dB or 32 dB
- low rail system for installation height from 400 mm
- high lift or vertical rail system for installation height from 1.500 mm
- panels in RAL color of choice based on wet painting or wrap foil
- set of light curtains
- Smoke detector for stand-alone system
- various switches
- explosion-proof (ATEX) components and marking
- liquid barrier with height 300 mm or 500 mm
classification: EI(1)
Fire resistance: 60 min.
max. opening width: 5.175 mm
max. opening height: 6.967 mm
Max opening: 23 m²
classification: EI(2)
Fire resistance: 90 min.
max. opening width: 5.175 mm
max. opening height: 6.967 mm
Max opening: 23 m²
classification: EW Fire resistance: 90 min. max. opening width: 5.175 mm max. opening height: 6.967 mm Max opening: 23 m²
OHD-C EI(1) 120 | EW 120
Certification and standards
The fire-rated overhead door is CE marked and tested according to several European standards:
- Tested in accordance with EN 1634-1
- classified in accordance with EN 13501‑2
- classified according to EN 13501-1 on fire class B-s1, d0
- validated cycle test in accordance with C3 (> 50.000 cycli)
- CE marked in accordance with EN 13241 and EN 16034
Application
- suitable for indoor / indoor and indoor / outdoor situations
- applicable in protected escape routes, not as an escape route
- suitable for frequent use
- mounting only possible on the wall / opening
- permissible mounting surfaces include: aerated concrete, sand-lime brick, concrete, masonry, fire-resistant steel construction
Standard configuration
Each door is standardly equipped with:
- gravity failsafe chain wheel drive 400 V incl. control box
- external gravity failsafe tubular motor 230 V incl. control box (till ± 11 m²)
- Anti-fall safety mechanism
- Visual and audible indicators
- rail system for installation height between 1.100 mm and 1.600 mm
- door leaf constructed from fire-resistant composite panels, thickness 80 mm, with a mixed white structure
Optional features
The door can be fitted with:
- application in indoor / outdoor situations up to wind class 5 (> 1.000 Pa)
- smoke-resistant version based on Sa
- burglar-resistant version (outside => inside) in accordance with RC 2 or RC 3
- sound insulation value 29 dB
- extra low rail system for installation height from 500 mm to ± 780 mm
- lowered rail fitting for overhead space between ± 780 mm and ± 1,099 mm
- high lift or vertical rail system for installation height from 1.600 mm
- panels in RAL color of choice based on wet painting
- set of light curtains
- Smoke detector for stand-alone system
- various switches
- explosion-proof (ATEX) components and marking
- liquid barrier with height 500 mm
classification: EI(1)
Fire resistance: 120 min.
max. opening width: 5.250 mm
max. opening height: 6.967 mm
Max opening: 23 m²
classification: EI(2)
Fire resistance: 120 min.
max. opening width: 5.250 mm
max. opening height: 6.967 mm
Max opening: 23 m²
classification: EW
Fire resistance: 120 min.
max. opening width: 5.250 mm
max. opening height: 6.967 mm
Max opening: 23 m²