Fire rated high-speed doors

Where fire safety is a priority

Fire rated high-speed doors

for frequent use

Fire- rated high-speed doors are always closed and only open when necessary. They are suitable for use between indoor areas, but also between indoors and outdoors. These doors can be used in protected escape routes, but are not intended as a direct escape route. Their fast operation makes them well suited for situations with high traffic or frequent use. Installation is only possible on the day, i.e. directly in or on the wall opening. The substrate must be suitable for secure fastening. Permitted installation substrates include aerated concrete, cellular concrete, sand-lime brick, concrete, masonry and fire-resistant coated steel structures. Translated with DeepL.com (free version)

Personal advice for the right solution

We do our best to provide as much information as possible on our website. However, you may still have specific questions about your situation. Our expert staff will be happy to help you with appropriate advice. Please feel free to contact us by e-mail or telephone. Together, we will find the best solution for your company.

Options, standards and certifications for fire-rated high-speed doors

OHD-C Sprint

Certification and standards

Indoor fire-rated high-speed doors are CE marked and tested according to several European standards:

  • Tested, double‑sided, compliant with EN 1634‑1
  • classified in accordance with EN 13501‑2
  • panels classified in accordance with EN 13501‑1 as fire class B‑s1, d0
  • validated endurance test at > 300.000 cycles
  • CE marked in accordance with EN 13241 and EN 16034

Application

  • basically always closed
  • suitable for indoor / indoor and indoor / outdoor situations
  • applicable in protected escape routes, not as an escape route
  • suitable for frequent use
  • mounting only possible on the wall / opening
  • permissible mounting surfaces include: aerated concrete, sand-lime brick, concrete, masonry, fire-resistant steel construction

Standard configuration

  • box motor 400 V incl. integrated safety catch device and control box with integrated frequency inverter
  • opening speed max. ± 1000 mm per second
  • closing speed max. ± 250 mm – ± 1000 mm per second
  • fully vertical rail system
  • set of light curtains
  • door leaf constructed from fire-resistant composite panels, thickness 42 mm, with a mixed white structure

Optional features

The door can be fitted with:

  • application in indoor / outdoor situations up to wind class 5 (> 1.000 Pa)
  • burglar-resistant version (outside => inside) in accordance with RC 2 or RC 3
  • sound insulation value 30 dB or 32 dB
  • highlift t.b.v. bovenruimte vanaf 1.500 mm
  • panels in RAL color of choice based on wet painting or wrap foil
  • Smoke detector for stand-alone system
  • various switches

classification: EI(1)
Fire resistance: 60 min.
max opening width: 4000 mm
Max opening height 4.500 mm
Max opening: 10 m²

classification: EI(2)
Fire resistance: 90 min.
max opening width: 4000 mm
Max opening height 4.500 mm
Max opening: 10 m²

classification: EW
Fire resistance: 90 min.
max opening width: 4000 mm
Max opening height 4.500 mm
Max opening: 10 m²